Learning path

  1. Gyroscope — what angular-rate measurements mean, calibration, bias, noise, and integration drift.
  2. Accelerometer — specific force, gravity-based tilt, vibration, bias, and linear-acceleration interference.
  3. 6-DoF IMU — how three axes of each sensor form a 6-axis inertial measurement unit.
  4. Sensor Fusion and Filtering — why neither sensor alone produces a reliable long-term attitude estimate.
  5. Complementary Filter — a simple practical roll/pitch filter.
  6. Kalman Filter for IMUs — a model-based filter that can estimate both attitude and gyro bias.
  7. BMI088 - Hardware Connection — wiring and initializing a real 6-axis IMU using I²C or SPI.

Data flow

flowchart TD
    G[Gyroscope: angular rate] --> CAL[Calibration, timing and unit conversion]
    A[Accelerometer: specific force] --> CAL
    CAL --> F[Sensor fusion]
    F --> C[Complementary filter]
    F --> K[Kalman / EKF]
    C --> R[Roll and pitch estimate]
    K --> R
    G --> Y[Yaw from integration; subject to drift]
    M[Magnetometer / external heading] -. optional correction .-> Y

Quick comparison

Measurement Strength Weakness Role in fusion
Gyroscope Fast response to rotation Bias causes integrated angle drift Short-term orientation changes
Accelerometer Gravity direction available when translation is negligible Vibrations and linear acceleration look like changes in tilt Long-term roll/pitch reference
6-axis IMU Both measurements in one system No absolute heading reference Estimates roll and pitch; yaw remains relative

Practical pipeline

BMI088 → I²C/SPI → raw samples → time stamps → calibration → physical units → complementary/Kalman fusion → estimated orientation