Kalman Filter for IMUs

Why use a Kalman filter?

A Kalman filter (KF) estimates a hidden state from a process model and noisy measurements, while tracking estimate uncertainty. For a 6-DoF IMU it can combine gyro-based changes with gravity-based tilt measurements and can explicitly estimate gyro bias.

Unlike a fixed-gain Complementary Filter, a KF uses process covariance QQ and measurement covariance RR to determine the correction gain. Neither technique fixes a missing physical measurement: yaw is still not absolutely observable from gyro + accelerometer alone.

Minimal 1-axis example: angle and gyro bias

Let the state be:

xk=[θkbk]\mathbf x_k=\begin{bmatrix}\theta_k\\ b_k\end{bmatrix}

and assume bb changes slowly. Using a measured gyro rate ωm,k\omega_{m,k} and sample interval Δt\Delta t:

xk−⏟predicted state=[1−Δt01]⏟Fxk−1++[Δt0]⏟Bωm,k\underbrace{\mathbf x_k^-}_{\text{predicted state}} = \underbrace{\begin{bmatrix}1&-\Delta t\\0&1\end{bmatrix}}_{F} \mathbf x_{k-1}^+ + \underbrace{\begin{bmatrix}\Delta t\\0\end{bmatrix}}_{B}\omega_{m,k}

The prediction covariance is:

Pk−=FPk−1+FT+QP_k^-=F P_{k-1}^+F^T+Q

The accelerometer, when gravity-dominated, supplies a tilt observation:

zk=θacc,k,H=[10]z_k=\theta_{acc,k},\qquad H=\begin{bmatrix}1&0\end{bmatrix}

The measurement update is:

yk=zk−Hxk−innovationSk=HPk−HT+Rinnovation varianceKk=Pk−HTSk−1Kalman gainxk+=xk−+Kkykcorrected statePk+=(I−KkH)Pk−(I−KkH)T+KkRKkT\begin{aligned} \mathbf y_k&=z_k-H\mathbf x_k^- &&\text{innovation}\\ S_k&=H P_k^-H^T+R &&\text{innovation variance}\\ K_k&=P_k^-H^TS_k^{-1} &&\text{Kalman gain}\\ \mathbf x_k^+&=\mathbf x_k^-+K_k\mathbf y_k &&\text{corrected state}\\ P_k^+&=(I-K_kH)P_k^-(I-K_kH)^T+K_kRK_k^T \end{aligned}

The last line is the numerically stable Joseph-form covariance update.

Practical steps

  1. Estimate startup gyro bias using stationary calibration.
  2. Initialize roll/pitch from a stable gravity-based tilt reading.
  3. Convert raw BMI088 values to consistent units and use accurate timestamps.
  4. Define reasonable initial covariance PP, process covariance QQ, and measurement variance RR.
  5. At each sample, predict using gyro measurements; when accelerometer tilt is reliable, update.
  6. During strong vibration/translation, increase RR or skip that observation, with care.
  7. Validate the estimated gyro bias, residuals, tilt response, and uncertainty against controlled tests.

KF vs. EKF

The example above is a linear small-scope angle/bias model, useful for learning and for mostly independent roll/pitch axes. Full 3D orientation is nonlinear; a practical filter often uses a quaternion-based extended Kalman filter (EKF) or error-state Kalman filter to model the relationship between rotation and sensed gravity properly.

Important limitation

An EKF cannot recover absolute heading without an external heading reference. It may track a relative yaw angle, but unobservable yaw bias eventually leads to drift. Add an appropriate magnetometer, visual reference, or other heading measurement if needed.

See also: Complementary Filter · Sensor Fusion and Filtering · 6-DoF IMU · BMI088 - Hardware Connection